Filter electric control cabinet
Filter electric control cabinet
Filter electric control cabinet
Filter electric control cabinet
Filter electric control cabinet
Filter electric control cabinet
EXW
Product details
Product Introduction

Device Introduction
Equipment Introduction

The filter electric control cabinet is the supporting equipment for the filter, used to connect to the factory's main power supply to provide power for the filter fan. It can also connect to the filter sensor to achieve functions such as detecting the pressure difference and wind pressure of the filter, making it a key auxiliary device to ensure the efficient and safe operation of the filter.

The filter electric control cabinet is an auxiliary device for the filter. It is used to connect to the factory's main power supply to supply power to the filter fan. It can also connect to the filter sensor to realize the detection of the filter's differential pressure, air pressure, etc., and is a key auxiliary device to ensure the efficient and safe operation of the filter.

Device Description
Device Description

After the electrical control cabinet is connected to the factory's main power supply, it provides power to the filter fan. Inside the cabinet, there are instruments such as pressure gauges connected to the filter, which can detect the pressure difference of the filter (the pressure difference between the inside and outside of the filter element, to determine the working status of the filter) and wind pressure (to monitor whether the fan is operating normally). At the same time, a communication interface is reserved to transmit relevant signals to the control system.

After this electric control cabinet is connected to the factory's main power supply, it supplies power to the filter fan. Instruments such as pressure gauges connected to the filter are installed in the cabinet, which can detect the differential pressure of the filter (the pressure difference inside and outside the filter element chamber to determine whether the filter is working properly) and air pressure (to monitor whether the fan is operating normally). At the same time, communication interfaces are reserved to transmit relevant signals to the control system.

Functions and Features
Functions and features

(1) Flexible start adaptation: The fan starting method can choose star-delta or variable frequency start, and the power of the inverter can be22kW - 45kWWithin the range, flexibly select according to the size of the filter air volume to meet different working condition requirements.
Flexible start-up adaptation: The fan start-up method can be selected as star-delta or frequency conversion start-up. The power of the frequency converter can be in the range of 22kW - 45kW, and can be flexibly selected according to the air volume of the filter to meet the needs of different working conditions.

(2) Intelligent frequency adjustment: After installing the frequency converter, the fan frequency can be intelligently adjusted according to the usage scenario. When there is no product spraying, the fan operating frequency is reduced to save energy consumption; when products are passing through, it switches to the normal working frequency to ensure filtration effectiveness; during the color change process, the fan operating frequency can be increased to optimize air volume.
Intelligent frequency adjustment: After installing the frequency converter, the fan frequency can be intelligently adjusted according to the usage scenario. When there is no product spraying, reduce the fan operating frequency to save energy consumption; when products pass through, switch to the normal working frequency to ensure the filtering effect; during the color changing process, the fan operating frequency can be increased to optimize the air volume.

(3) Precise monitoring operation: Equipped with a differential pressure gauge, it can detect the pressure difference between the inside and outside of the filter element, accurately determining whether the filter's working status is normal; it is equipped with a wind pressure gauge, which can monitor the fan's operating condition in real time and promptly detect anomalies.
Accurate monitoring of operation: Equipped with a differential pressure gauge, it can detect the pressure difference inside and outside the filter element chamber to accurately determine whether the filter is working properly; an air pressure gauge is provided to monitor the operation of the fan in real time and detect abnormalities in a timely manner.

(4) Reliable protection and communication: Equipped with overcurrent and overload protection functions, effectively ensuring the safe operation of the motor; reserved communication interface, which can transmit various signals of the device operation to the control system, facilitating centralized monitoring and management.
Reliable protection and communication: It has over-current and overload protection functions to effectively ensure the safe operation of the motor; communication interfaces are reserved to transmit various signals of the equipment's operation to the control system, facilitating centralized monitoring and management.

Parameter
parameter

Parameter Item
Parameter items

Content

Detail

Device Size
Equipment size:

800mm×435mm×1700mm

Rated Voltage

Rated voltage

380V±10%50 - 60Hz

Signal transmission voltage

Signal transmission voltage

24V AC